{"id":222,"date":"2019-11-28T10:05:21","date_gmt":"2019-11-28T16:05:21","guid":{"rendered":"https:\/\/wpsites.ucalgary.ca\/iaml\/?page_id=222"},"modified":"2021-01-27T10:33:52","modified_gmt":"2021-01-27T16:33:52","slug":"film-slide-scanner","status":"publish","type":"page","link":"https:\/\/wpsites.ucalgary.ca\/iaml\/support\/film-slide-scanner\/","title":{"rendered":"Film Slide Scanner"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Using VueScan Software on a Nikon Film Scanner<\/h2>\n\n\n\n<p><cite>Note 1: The best possible results can only be achieved with clean slides and negatives. Before scanning, remove dust from the film with a blower and wipe the slide or negative gently with a soft, dry cloth to remove fingerprints. We do also have a duster available on request. <\/cite><\/p>\n\n\n\n<p><cite>Note 2: If you need to scan medium-size negatives (or you need to do a large volume of film in a short time), use the Epson Perfection V700, which is a flatbed with a transparency bed as well. General information on the Epson scanners is found under <a href=\"https:\/\/wpsites.ucalgary.ca\/iaml\/support\/flatbed-scanner\/\">Flatbed Scanning.<\/a><\/cite><\/p>\n\n\n\n<p><strong> Are you scanning <a href=\"#slides\">35 mm slides<\/a><\/strong><strong> or <\/strong><strong><a href=\"#negs\">negative strips\/large-format film<\/a>?<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"slides\">Scanning 35 mm Slides<\/h3>\n\n\n\n<p>The Nikon Coolscan V comes with two different film readers that can be used interchangeably. The slide reader is the one that sits flush with the face of the scanner when inserted. The negative strip reader protrudes from the face of the scanner by about 5 cm. One should be inserted and the other sitting next to the scanner. You may switch the readers as needed. If you are uncomfortable switching readers, ask Lab staff to assist you.<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Turn the scanner on. (The scanner must be on before the scanning software is launched.)<\/li><li>Determine which side of the slide should be facing up. Film has an emulsion surface and a base; when examined under a light, the emulsion side is dull and the base shiny. Viewed from the base side, the image appears exactly as it would in a printed photograph. We want the <strong>base (shiny side) facing up<\/strong>.<\/li><li>Insert the slide smoothly into the scanner with the base (shiny side) up and the short side of the aperture facing the scanner (i.e. in portrait orientation). Stop when the slide contacts the back of the slot. The correct orientations for inserting the slides are shown below. (Of course, if you accidentally rotate the slide 180\u00b0, you can use the slide scanning software to correct the error.) <\/li><\/ol>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"358\" height=\"267\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/cs_portrait.gif\" alt=\"\" class=\"wp-image-384 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 358px; --smush-placeholder-aspect-ratio: 358\/267;\" \/><figcaption>Portrait goes straight in.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"358\" height=\"271\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/cs_landscape.gif\" alt=\"\" class=\"wp-image-386 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 358px; --smush-placeholder-aspect-ratio: 358\/271;\" \/><figcaption>Landscape narrow side goes in.<\/figcaption><\/figure>\n\n\n\n<p>Do <em>not<\/em> insert the slide with the long side of the aperture facing the scanner (i.e. in landscape orientation). The scanner will be unable to scan the edges of the film.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"358\" height=\"232\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/cs_do_not.gif\" alt=\"\" class=\"wp-image-388 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 358px; --smush-placeholder-aspect-ratio: 358\/232;\" \/><\/figure>\n\n\n\n<p>4. You are ready to launch the VueScan software, which is located in the Applications folder. A simple way to launch the software is by searching for VueScan in Spotlight (triggered by clicking the magnifying glass icon at the top right of the computer screen or by pressing Command-Space).<\/p>\n\n\n\n<p>5. In the top left portion of the VueScan window, you will see a set of control tabs (pictured below). Take time to make sure your settings are correct. If you are an advanced user and want ultimate control, select the Input tab and then choose <strong>Professional<\/strong> instead of Standard under Options (at the top of the Input settings list).<\/p>\n\n\n\n<p>6. In the Input tab, specifically, set&#8230;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"513\" height=\"603\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-6-standard.png\" alt=\"\" class=\"wp-image-390 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-6-standard.png 513w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-6-standard-255x300.png 255w\" data-sizes=\"(max-width: 513px) 85vw, 513px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 513px; --smush-placeholder-aspect-ratio: 513\/603;\" \/><\/figure>\n\n\n\n<p><em>Media<\/em>&nbsp;to&nbsp;Slide film<\/p>\n\n\n\n<p><em>Scan resolution<\/em>&nbsp;to&nbsp;4000 dpi<\/p>\n\n\n\n<p>This will allow you to print the image, scanned from a full size frame slide or negative, on the following media:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>13&#8243; by 19&#8243; sheet at best quality<\/li><li>24&#8243; roll (by 36&#8243;) maximum without significant quality loss and digital manipulation.<\/li><\/ul>\n\n\n\n<p>Please ask staff about ON1 Resize software if you need to print at larger sizes.<\/p>\n\n\n\n<p><em>Rotation<\/em>&nbsp;as necessary (if your slide is Landscape\/wide, for example, you may need to select either Left or Right)<br><br>7. Skip to the Color tab, and ensure settings are as shown below.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"512\" height=\"422\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-7-standard.png\" alt=\"\" class=\"wp-image-392 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-7-standard.png 512w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-7-standard-300x247.png 300w\" data-sizes=\"(max-width: 512px) 85vw, 512px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 512px; --smush-placeholder-aspect-ratio: 512\/422;\" \/><\/figure>\n\n\n\n<p>If your film slides are Kodak, select this option from the Slide vendor drop-down list. Choose your Slide brand and Slide type as appropriate. Pay attention, particularly, to these settings:<br><em>Printer color space<\/em>: sRGB (Professional mode only; not pictured)<br><em>Output color space<\/em>: ProPhoto RGB<br><em>Monitor color space<\/em>: ProPhoto RGB<\/p>\n\n\n\n<p>8. While still in the Color tab, press the&nbsp;<strong>Preview<\/strong>&nbsp;button at the bottom left of the VueScan screen. Now that you have an image preview to work with:<br><br>Check out&nbsp;<em>Color balance<\/em>&nbsp;options and find the best ones for your image.<\/p>\n\n\n\n<p>9. Press&nbsp;<strong>Scan<\/strong>. After the image has scanned, press&nbsp;<strong>Preview<\/strong>&nbsp;again. This eliminates a potential bug that crops up on the first scan done after start-up of the program. Now, you can continue to work with your image.<\/p>\n\n\n\n<p>10. Adjust the marquee rectangle to specify the size of your final scan by click-and-dragging the rectangle edges with your mouse. If you want other crop options, you can go to the Crop tab and use the&nbsp;<em>Crop size<\/em>&nbsp;drop-down menu. It contains pre-set crop size options. Selecting Manual will allow you to adjust the rectangle size by entering X and Y sizes numerically, or click-and-dragging.The resulting rectangle outlines what the scanner will actually capture as your scanned image.&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"519\" height=\"405\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-10-standard.png\" alt=\"\" class=\"wp-image-394 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-10-standard.png 519w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-10-standard-300x234.png 300w\" data-sizes=\"(max-width: 519px) 85vw, 519px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 519px; --smush-placeholder-aspect-ratio: 519\/405;\" \/><\/figure>\n\n\n\n<p>11. In the Filter tab, you may want to check out the results of selecting&nbsp;<em>Infrared clean<\/em>&nbsp;and&nbsp;<em>Sharpen<\/em>&nbsp;options.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"513\" height=\"249\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-11-standard.png\" alt=\"\" class=\"wp-image-396 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-11-standard.png 513w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-11-standard-300x146.png 300w\" data-sizes=\"(max-width: 513px) 85vw, 513px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 513px; --smush-placeholder-aspect-ratio: 513\/249;\" \/><\/figure>\n\n\n\n<p>Below are two image parts for comparison<\/p>\n\n\n\n<figure class=\"wp-block-table aligncenter\"><table><tbody><tr><td><img decoding=\"async\" width=\"290\" height=\"147\" class=\"wp-image-398 lazyload\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/tab3_filter_no_filter.png\" alt=\"\" style=\"--smush-placeholder-width: 290px; --smush-placeholder-aspect-ratio: 290\/147;width: 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\"><\/td><td><img decoding=\"async\" width=\"290\" height=\"147\" class=\"wp-image-400 lazyload\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/tab3_filter_light_infraclean_sharpen.png\" alt=\"\" style=\"--smush-placeholder-width: 290px; --smush-placeholder-aspect-ratio: 290\/147;width: 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\"><\/td><\/tr><tr><td>No Filters<\/td><td>Light infrared clean, <br>Sharpen checked<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>12. Finally, in the Output tab, make sure the options shown below are selected.<\/p>\n\n\n\n<p>Select Fixed dpi under the Printed size drop-down menu.<br>The Printed dpi option will pop up. Enter 300.<br>Enter in your preferred file name (instead of &#8220;myname1&#8221;)<\/p>\n\n\n\n<p>Make sure TIFF file is checked. VueScan is also able to create multiple files of different formats from the same scan when in Professional Mode; just check off the file types you need.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"517\" height=\"413\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-12-standard.png\" alt=\"\" class=\"wp-image-402 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-12-standard.png 517w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-12-standard-300x240.png 300w\" data-sizes=\"(max-width: 517px) 85vw, 517px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 517px; --smush-placeholder-aspect-ratio: 517\/413;\" \/><\/figure>\n\n\n\n<p>13. Feel free to go back to any of the tabs and adjust your settings as necessary.<br>If you are looking for more colour adjustment options, click the&nbsp;<strong>More<\/strong>&nbsp;button at the bottom of the VueScan screen, and go through each of the tabs again; Color and Input tabs, especially, will have added functionality in this area.<\/p>\n\n\n\n<p>14. Press the&nbsp;<strong>Scan<\/strong>&nbsp;button and wait for your image to appear.<\/p>\n\n\n\n<p>15. If you need to re-adjust your crop marks and want the marquee box to come up again, switch to the Preview tab located to the far right of the other tabs, and above the scanned image.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"616\" height=\"248\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/preview_scan_top.jpg\" alt=\"\" class=\"wp-image-404 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/preview_scan_top.jpg 616w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/preview_scan_top-300x121.jpg 300w\" data-sizes=\"(max-width: 616px) 85vw, 616px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 616px; --smush-placeholder-aspect-ratio: 616\/248;\" \/><\/figure>\n\n\n\n<p>16. <strong>Scan<\/strong>&nbsp;again as necessary.<\/p>\n\n\n\n<p>17. Remove your slide by pressing the scanner\u2019s eject button.<\/p>\n\n\n\n<p>18. Insert next slide and repeat steps 5\u201318 until you have completed all your scanning.<\/p>\n\n\n\n<p>19. Quit the program (VueScan &gt; Quit) when you are done.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"negs\">Scanning 35 mm Negative Strips<\/h2>\n\n\n\n<p>The Nikon Coolscan V comes with two different film readers that can be used interchangeably. The slide reader is the one that sits flush with the face of the scanner when inserted. The negative strip reader protrudes from the face of the scanner by about 5 cm. One should be inserted and the other sitting next to the scanner. You may switch the readers as needed. If you are uncomfortable switching readers, ask Lab staff to assist you.<\/p>\n\n\n\n<p><em>The large-format Epson Perfection V700 comes with various carriers for film and other transparent media, which are kept beside the scanner. These carriers accommodate sizes larger than 35 mm. Feel free to ask Lab staff for assistance if you are unsure about using these. Information on Epson scanners is found in <a href=\"https:\/\/wpsites.ucalgary.ca\/iaml\/support\/flatbed-scanner\/\">Flatbed Scanning<\/a>.<\/em><\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Turn the scanner on. (The scanner must be on before the scanning software is launched.)<\/li><li>You are ready to launch the VueScan software. Click on the Launchpad icon in the Dock (on the lower far left) or launch it by searching for VueScan in Spotlight (detective lens at the top right of the computer screen).<\/li><li>Determine which side of the film should be facing up. Film has an emulsion surface and a base; when examined under a light, the emulsion side is dull and the base shiny. We want the&nbsp;<strong>base (shiny side) facing up<\/strong>. Another way to determine this is to insert the film with the curl of it facing down\/inward. The reader will automatically draw the strip in.<\/li><li>In the top left portion of the VueScan window, you will see a set of control tabs (pictured below). Take time to make sure your settings are correct. If you are an advanced user and want ultimate control, select the Input tab and then choose&nbsp;<strong>Professional<\/strong>&nbsp;instead of Standard under Options (at the top of the Input settings list).<\/li><li>In the Input tab, specifically, set&#8230;<\/li><\/ol>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"513\" height=\"602\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part-2-step-5-standard.png\" alt=\"\" class=\"wp-image-406 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part-2-step-5-standard.png 513w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part-2-step-5-standard-256x300.png 256w\" data-sizes=\"(max-width: 513px) 85vw, 513px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 513px; --smush-placeholder-aspect-ratio: 513\/602;\" \/><\/figure>\n\n\n\n<p><em>Media<\/em>&nbsp;to&nbsp;Color negative&nbsp;or&nbsp;B&amp;W negative, as appropriate.<\/p>\n\n\n\n<p><em>Scan resolution<\/em>&nbsp;to&nbsp;4000 dpi<\/p>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<p>This will allow you to print the image, scanned from a full size frame slide or negative, on the following media:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>13&#8243; by 19&#8243; sheet at best quality<\/li><li>24&#8243; roll (by 36&#8243;) maximum without significant quality loss and digital manipulation.<\/li><\/ul>\n\n\n\n<p>Please ask staff about ON1 Resize software if you need to print at larger sizes.<\/p>\n<\/div><\/div>\n\n\n\n<p><em>Rotation<\/em>&nbsp;as necessary (if your slide is Landscape\/wide, for example, you may need to select either Left or Right)<\/p>\n\n\n\n<p>6. To preview and scan a single frame, enter the Frame number in the Input tab, and make sure Batch scan is set to &#8220;Off&#8221;. Press&nbsp;<strong>Preview<\/strong>.<\/p>\n\n\n\n<p>7. Press&nbsp;<strong>Scan<\/strong>. After the image has scanned, press&nbsp;<strong>Preview<\/strong>&nbsp;again. This eliminates a potential bug that crops up on the first scan done after start-up of the program. Now, you can continue to work with your image.<\/p>\n\n\n\n<p>8. If you are not doing a batch scan, skip step 9 and continue to step 10.<\/p>\n\n\n\n<p>9. You are able to preview and scan your film strip in batches of frames, though there is no ability to modify any frame settings while a scan is in progress. To set up a batch scan:<br><br>Select&nbsp;<em>Batch scan<\/em>&nbsp;settings (&#8220;All&#8221; will scan all frames, &#8220;List&#8221; will allow you to select specific frame numbers)Press the&nbsp;<strong>Preview<\/strong>&nbsp;button and wait for the images to appear. You will be able to flip between the frame previews using the arrows at the bottom right of the VueScan screen.Adjust the crop marquee box as necessary on each frame. This will be the area of the final scan.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"369\" height=\"94\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/film_bottomright_arrows.png\" alt=\"\" class=\"wp-image-408 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/film_bottomright_arrows.png 369w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/film_bottomright_arrows-300x76.png 300w\" data-sizes=\"(max-width: 369px) 85vw, 369px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 369px; --smush-placeholder-aspect-ratio: 369\/94;\" \/><\/figure>\n\n\n\n<p>If you want other crop options, you can go to the Crop tab and use the&nbsp;<em>Crop size<\/em>&nbsp;drop-down menu. It contains pre-set crop size options. Selecting Manual will allow you to adjust the rectangle size by entering X and Y sizes numerically, or click-and-dragging the crop marks.The resulting rectangle outlines what the scanner will actually capture as your scanned image.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"519\" height=\"405\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part2-step-10-standard.png\" alt=\"\" class=\"wp-image-410 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part2-step-10-standard.png 519w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part2-step-10-standard-300x234.png 300w\" data-sizes=\"(max-width: 519px) 85vw, 519px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 519px; --smush-placeholder-aspect-ratio: 519\/405;\" \/><\/figure>\n\n\n\n<p>10. Skip to the Color tab, and ensure settings are as shown below.<br><\/p>\n\n\n\n<p>If you know your film type, select it from the&nbsp;<em>Negative vendor<\/em>,&nbsp;<em>brand<\/em>, and&nbsp;<em>type<\/em>drop-down lists.<\/p>\n\n\n\n<p>Adjust&nbsp;<em>Color balance<\/em>&nbsp;options to get the image you want.<\/p>\n\n\n\n<p>Pay attention, particularly, to these settings:<\/p>\n\n\n\n<p><em>Printer color space<\/em>: sRGB (Professional mode only; not pictured)<br><em>Output color space<\/em>: ProPhoto RGB<br><em>Monitor color space<\/em>: ProPhoto RGB<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"500\" height=\"406\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part-2-step-10-standard.png\" alt=\"\" class=\"wp-image-412 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part-2-step-10-standard.png 500w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/part-2-step-10-standard-300x244.png 300w\" data-sizes=\"(max-width: 500px) 85vw, 500px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 500px; --smush-placeholder-aspect-ratio: 500\/406;\" \/><\/figure>\n\n\n\n<p>11. In the Filter tab, you may want to check out the results of selecting&nbsp;<em>Infrared clean<\/em>&nbsp;and&nbsp;<em>Sharpen<\/em>&nbsp;options.&nbsp;<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"513\" height=\"249\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-11-standard.png\" alt=\"\" class=\"wp-image-396 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-11-standard.png 513w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-11-standard-300x146.png 300w\" data-sizes=\"(max-width: 513px) 85vw, 513px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 513px; --smush-placeholder-aspect-ratio: 513\/249;\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table aligncenter\"><table><tbody><tr><td><img decoding=\"async\" width=\"290\" height=\"147\" class=\"wp-image-398 lazyload\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/tab3_filter_no_filter.png\" alt=\"\" style=\"--smush-placeholder-width: 290px; --smush-placeholder-aspect-ratio: 290\/147;width: 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\"><\/td><td><img decoding=\"async\" width=\"290\" height=\"147\" class=\"wp-image-400 lazyload\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/tab3_filter_light_infraclean_sharpen.png\" alt=\"\" style=\"--smush-placeholder-width: 290px; --smush-placeholder-aspect-ratio: 290\/147;width: 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\"><\/td><\/tr><tr><td>No Filters<\/td><td>Light infrared clean, <br>Sharpen checked<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>12. Finally, in the Output tab, make sure the options shown below are selected.<br><\/p>\n\n\n\n<p>Select&nbsp;Fixed dpi&nbsp;under the&nbsp;<em>Printed size<\/em>&nbsp;drop-down menu<\/p>\n\n\n\n<p>The&nbsp;<em>Printed dpi<\/em>&nbsp;option will pop up. Enter&nbsp;300.<\/p>\n\n\n\n<p>Enter in your&nbsp;preferred file name&nbsp;(instead of &#8220;myname1&#8221;).&nbsp;<\/p>\n\n\n\n<p>Make sure&nbsp;<em>TIFF file<\/em>&nbsp;is checked. VueScan is also able to create multiple files of different formats from the same scan when in Professional Mode; just check off the file types you need. The Raw file will contain no post-scan processing, so if you are looking to have the actual negative image, select this option. Selecting the output to only Raw is also one way to speed up the batch scanning process, but this may also mean extra digital image processing for you later on.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"517\" height=\"413\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-12-standard.png\" alt=\"\" class=\"wp-image-402 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-12-standard.png 517w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/step-12-standard-300x240.png 300w\" data-sizes=\"(max-width: 517px) 85vw, 517px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 517px; --smush-placeholder-aspect-ratio: 517\/413;\" \/><\/figure>\n\n\n\n<p>If you will be working in 16 bit colour with Photoshop, in Professional mode you can select the&nbsp;48 bit RGB&nbsp;setting under&nbsp;<em>TIFF file type<\/em>. For B&amp;W film, either&nbsp;8 bit Gray&nbsp;or&nbsp;16 bit Gray&nbsp;will suffice.<\/p>\n\n\n\n<p>13. Feel free to go back to any of the tabs and adjust your settings as necessary.<br>If you are looking for more colour adjustment options, click the&nbsp;<strong>More<\/strong>&nbsp;button at the bottom of the VueScan screen, and go through each of the tabs again; Color and Input tabs, especially, will have added functionality in this area.&nbsp;If you are scanning a batch of frames, and want to apply exactly the same options under one of the tabs, across all frames, click&nbsp;<strong>More<\/strong>&nbsp;and select the &#8220;All frames&#8221; checkbox. Be aware that even if you then uncheck this box, the settings will stay on all frames, and any previously-set, frame-specific options under that tab will be lost.<\/p>\n\n\n\n<p>14. Press the&nbsp;<strong>Scan<\/strong>&nbsp;button and wait for your images to appear. VueScan may ask you to provide different naming options, depending on how you&#8217;ve set up the Output tab. For this reason it is best not to walk away and assume that the entire batch will be finished scanning when you come back.<\/p>\n\n\n\n<p>15. If you need to re-adjust your crop marks and want the marquee box to come up again, switch to the Preview tab located above the scanned image.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"616\" height=\"248\" data-src=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/preview_scan_top.jpg\" alt=\"\" class=\"wp-image-404 lazyload\" data-srcset=\"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/preview_scan_top.jpg 616w, https:\/\/wpsites.ucalgary.ca\/iaml\/wp-content\/uploads\/sites\/44\/2019\/11\/preview_scan_top-300x121.jpg 300w\" data-sizes=\"(max-width: 616px) 85vw, 616px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 616px; --smush-placeholder-aspect-ratio: 616\/248;\" \/><\/figure>\n\n\n\n<p>16. <strong>Scan<\/strong>&nbsp;again as necessary, following steps 4-14 as appropriate.<\/p>\n\n\n\n<p>17. To remove your film strip, go to the Scanner menu and select Eject or press Command-J.<\/p>\n\n\n\n<p>18. Quit the program (VueScan &gt; Quit) when you are done.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Using VueScan Software on a Nikon Film Scanner Note 1: The best possible results can only be achieved with clean slides and negatives. Before scanning, remove dust from the film with a blower and wipe the slide or negative gently with a soft, dry cloth to remove fingerprints. We do also have a duster available &hellip; <a href=\"https:\/\/wpsites.ucalgary.ca\/iaml\/support\/film-slide-scanner\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Film Slide Scanner&#8221;<\/span><\/a><\/p>\n","protected":false},"author":89,"featured_media":0,"parent":127,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-222","page","type-page","status-publish","hentry"],"featured_image_src":null,"featured_image_src_square":null,"_links":{"self":[{"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/pages\/222","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/users\/89"}],"replies":[{"embeddable":true,"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/comments?post=222"}],"version-history":[{"count":7,"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/pages\/222\/revisions"}],"predecessor-version":[{"id":879,"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/pages\/222\/revisions\/879"}],"up":[{"embeddable":true,"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/pages\/127"}],"wp:attachment":[{"href":"https:\/\/wpsites.ucalgary.ca\/iaml\/wp-json\/wp\/v2\/media?parent=222"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}